2 edition of On-line Zeeman atomic absorption spectroscopy for mecury analysis in oil shale gases found in the catalog.

On-line Zeeman atomic absorption spectroscopy for mecury analysis in oil shale gases

D. C Girvin

On-line Zeeman atomic absorption spectroscopy for mecury analysis in oil shale gases

by D. C Girvin

  • 155 Want to read
  • 13 Currently reading

Published by Industrial Environmental Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency, Available to the public through the National Technical Information Service in Cincinnati, Ohio, Springfield, Va .
Written in English

    Subjects:
  • Mercury -- Analysis,
  • Atomic absorption spectroscopy,
  • Air -- Pollution

  • Edition Notes

    Statementby D.C. Girvin and J.P. Fox
    SeriesInteragency energy/environment R&D program report -- EPA-600/7-80-130, Research reporting series -- EPA-600/7-80-130
    ContributionsFox, J. P, Industrial Environmental Research Laboratory (Cincinnati, Ohio). Program Operations Office, Industrial Environmental Research Laboratory (Cincinnati, Ohio), Lawrence Berkeley Laboratory. Energy and Environment Division
    The Physical Object
    Paginationxiv, 96 p. :
    Number of Pages96
    ID Numbers
    Open LibraryOL16801834M

    Several elements (Zn, Pb, Cu, Ni, Ca, Mg, Fe, and Mn) are determined routinely in water samples using atomic absorption spectroscopy. Sodium and potassium are determined by flame emission. The preparation of the samples, the analytical method, the detection . United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science CLG-MERC Page 6 of 10 Title: Determination of Mercury by Atomic Absorption Spectroscopy Revision: 01 Replaces: CLG -MERC Effective: 05/27/ h. Swirl to mix the contents thoroughly and pipet 10 mL of the contents from each.

    Spectrochemical Analysis by Atomic Absorption and Emission provides this knowledge, by describing both the theory of atomic spectroscopy and all the major atomic spectrometric techniques (AAS, Flame-AES, Plasma AES, AFS, and ICP-MS), including basic concepts, instrumentation and by: Notes on atomic absorption spectroscopy pdf DOWNLOAD! DIRECT DOWNLOAD! Notes on atomic absorption spectroscopy pdf Atomic absorption spectroscopy is based on the same principle as the flame test used in qualitative analysis. When an alkali metal salt or a calcium, strontium the atomic absorption spectrometry is in the.

    ON LINE ZEEMAN ATOMIC ABSORPTION SPECTROMETER FOR MERCURY ANALYSIS IN OIL SHALE OFF GASES (Courtesy of the Technical Information Division, University of California, Lawrence Berkeley Laboratory) FIGURE 4. Simple method for determination of Pb in natural water by flame atomic absorption spectrometry (FAAS) has calibration graph for lead was linear in the range ( ) µg ml -1 and the detection limit was x 10 -3 µgL


Share this book
You might also like
Double-barrel

Double-barrel

Two articles from the Princeton review

Two articles from the Princeton review

The Structure of Political Communication in the United Kingdom, the United States, and the Federal Republic of Germany (European University Studies,)

The Structure of Political Communication in the United Kingdom, the United States, and the Federal Republic of Germany (European University Studies,)

fastest funny car

fastest funny car

Uniqueness of the therapeutic relationship

Uniqueness of the therapeutic relationship

Food packaging

Food packaging

Grizzly bears

Grizzly bears

District Health Council

District Health Council

Hydrogeology and ground-water quality of Brunswick County, North Carolina

Hydrogeology and ground-water quality of Brunswick County, North Carolina

Views on the Serbo-Croatian language service at the Voice of America

Views on the Serbo-Croatian language service at the Voice of America

Sociology and the New Testament

Sociology and the New Testament

Services and environmental engineering

Services and environmental engineering

Elevated motorway sports centre.

Elevated motorway sports centre.

With the left hand

With the left hand

On-line Zeeman atomic absorption spectroscopy for mecury analysis in oil shale gases by D. C Girvin Download PDF EPUB FB2

SECTION 2 CONCLUSIONS A new Zeeman atomic absorption (ZAA) spectrometer was designed and built to make continuous on-line measurements of mercury in the off-gas from oil.

On-line Zeeman atomic absorption spectroscopy for mercury analysis in oil shale gases, Volume 1. On-line Zeeman atomic absorption spectroscopy for mercury analysis in oil shale gases.

Cincinnati, Ohio: Industrial Environmental Research Laboratory, Office of Research and Development, U.S. Environmental Protection Agency ; Springfield, Va.: Available to the public through the National Technical Information Service, (OCoLC) on-line zeeman atomic absorption spectroscopy for mercury analysis in oil shale gases.

final reportAuthor: D.C. Girvin, J.P. Fox. On-line Zeeman atomic absorption spectroscopy for mercury analysis in oil shale gases / By D. Girvin, J. Fox, Lawrence Berkeley Laboratory.

Energy and Environment Division., Ohio) Industrial Environmental Research Laboratory (Cincinnati and Ohio). In atomic absorption spectroscopy we deal with atoms at ground stage, these atoms absorb a characteristic wavelength of radiations coming from the source which is commonly a hollow cat-hod lamp.

It requires high energy and the resonance line is below nm. Koizumi and K. Uchino, “Atomic absorption analysis for mercury using the Zeeman effect,” Hitachi Hyoron, 56, No.

11, – (). Google Scholar Cited by: 2. Mercury analysis by new Zeeman AAS Zeeman shift (mK) Fig. Experimental dependence of the differential signal 5 on the magnetic field strength (the inverse Zeeman effect and transverse magnetic field), (a) Normal composition, (b) enriched ""Hg composition.

5, is a signal related to the variation in the ""Hg/^Hg abundance ratio in the sample. 5 10 15 20 Variation Cited by: The accuracy of the method is 20% [52] Real-time GEM measurements in air were carried out using a portable Lumex (+) analyzer.

This device is based on Zeeman Atomic Absorption Spectrometry using High Frequency Modulation of Light Polarization (ZAAS-HFM; [51]). Place approximately g of the homogenized tissue (muscle, liver, or.

kidney), or g hair, into a tared mL pear-shaped flask, taking care that all. of the sample is deposited in the bottom of the flask and none is left in the neck.

Zinc is determined by atomic absorption spectrometry by direct aspiration of the sample into an air-acetylene flame. The procedure may be automated by the addition of a sampler and either a strip-chart recorder or a printer or both.

Interferences Magnesium at concentrations greater than mg/L interferes unless other cations File Size: KB. Gaseous Hg emissions were measured during the processing of a large modified in-situ oil shale retort (4× m3) in Colorado.

A continuous, on-line, g Cited by: 4. ASTM D(), Standard Test Method for Total Mercury in Crude Oil Using Combustion and Direct Cold Vapor Atomic Absorption Method with Zeeman Background Correction, ASTM International, West Conshohocken, PA, Mercury emissions from a modified in-situ oil shale retort.

on-line, gas monitor based upon the principal of Zeeman atomic absorption spectroscopy was the primary analytical method. This practice is known as atomic absorption spectroscopy (AAS).

AAS was first deployed back in by Gustav Kirschoff and Robert Bunsen to detect the presence of certain atoms in flames and gases. Since then, the modern approach to AAS has been revolutionised, most noticeably by A. Walsh and C. Alkemade in the s. An atomic absorption spectrometry for the quantification of zink (Zn) and mercury analyzer for the quantification of mercury (Hg) levels in cream cosmetic were developed and validated.

The method was validated for linearity and range, precision, accuracy, limit Cited by: 3. AtomicAbsorption 24 Zeeman Background Zeeman Background Correction is used mainly in graphite furnace atomic absorption systems. When an atom is placed in a magnetic field and its absorption of observed in polarized light, the normal single line is split into three components – б- π and б +displaced symmetrically about the normal position.

This test method can be used to determine the total mercury concentration of a natural gas stream down to μg/m can be used to assess compliance with environmental regulations, predict possible damage to gas plant equipment, and monitor the efficiency of mercury removal beds.

C Girvin has written: 'On-line Zeeman atomic absorption spectroscopy for mecury analysis in oil shale gases' -- subject(s): Mercury, Atomic absorption spectroscopy, Air, Analysis, Pollution. Using an RA + Zeeman atomic absorption spectrometer, the concentration of mercury was measured in the air above objects of interest.

The measurements mainly made from driving a car equipped with a GPS receiver have allowed the assignment of Hg concentration to a particular place to provide a digitised pollution database in geographic Author: Egils Bogans, Janis Skudra, Anda Svagere, Zanda Gavare.

Experimental and Numerical Analysis of Gas Transport in Shale Including the Role of Sorption History Matching, Shale Oil Results highlight the interplay of gas slip and sorption of pure gases at core-level.

Results also quantify the role of CO2 sorption in various shale fabrics and thus promote the potential for by: Comment: This is an ex-library book and may have the usual library/used-book markings book has hardback covers. In good all round condition. Dust Jacket in fair condition. Please note the Image in this listing is a stock photo and may not match the covers of the actual itemCited by: Mercury analysis is a critical test process that requires specific standard.

Using the right mercury analyzer to ensure that you achieve the right results. Atomic Fluorescence Spectroscopy offers the highest level of sensitivity and linearity.